Grounding operations are the process of connecting the inactive parts and the zero conductive parts in a electrical installation with the help of an electrode to the ground. In other words, wherever electrical energy is used, it is necessary to connect the mineral parts which can carry current on it with the soil. The purpose of grounding operations is to prevent the danger of a malfunction in the event of a malfunction or malfunction, and to eliminate these dangerous voltages completely.

The yellow green cable on the electronic means is ground and is indicated by PE. Most of the short circuits occurring in electrical networks are short-phase short circuits. The phase and neutral must be 220-230 volts. For a good grounding between neutral and ground, this value should be most 1-2 volts.

Groundis very important in terms of human life and property security. It is the best method to prevent possible electrical hazards. This is also useful for the long life of the electric vehicle.

generators electricity generating tools. They convert mechanical energy into electrical energy. The source of mechanical energy here can be a steam engine, an internal combustion engine or a wind turbine. In contrast to generators, electric motors are the ones that convert electrical energy into mechanical energy. In fact, electric motors and generators have many things in terms of working principles.

Generators are electricity that naturally endangers human life because they produce electricity. Therefore, it must be grounded in order to prevent possible electrical leakages. The fault currents that will occur on the generators with the grounding process are limited by resistance and transmitted to the ground, thus ensuring the safety of life and property. This also prevents voltage build-up on the generator. Therefore, regular maintenance of the generators is required.

This obligation introduces the Occupational Health and Safety Law and the Health and Safety Requirements Regulation on the Use of Work Equipment. All kinds of health and safety measures must be taken, and the minimum requirements to be observed are included in these legal regulations.

In the tables of Annex 3 Maintenance, Repair and Periodic Controls in the annexes to the Regulation on Health and Safety Conditions in the Use of Work Equipment, generators, Electrical Installation, Grounding Installation, Lightning arrester group are included. For generators, at least once a year periodic check-up and their mines are required.

According to the regulation, periodic inspections of the earthing of electrical installations, as well as the periodic inspection of the generator grounding must be made by electrical engineers, electrical technicians or high technicians.

During these inspections, Regulation on Grounding in Electrical Installations, Regulation on Electrical High Current Plants and Electrical Internal Facilities Regulation and Electrical equipment - Part 60079: The requirements for the design, selection and assembly of electrical installations must be complied with.

TÜRCERT certification body is also testing and inspection services also gives. TÜRCERT is ready to provide all services to organizations in every sector with its experienced managers and employees, if you want to get more information about generator ground periodic inspection or to make these examinations and inspections.